Repository logo
Home
Research Outputs
Statistics
  1. Home
  2. SuUB
  3. Dissertationen
  4. Laser-interferometric dilatometry
Citation link
https://nbn-resolving.de/urn:nbn:de:gbv:46-00106113-10

Laser-interferometric dilatometry

Date Issued
2017-10-04
Author(s)
Spannagel, Ruven
Supervisors
Braxmaier, Claus
Referees
Rittweger, Andreas
Braxmaier, Claus
Abstract
Highly dimensionally stable materials and structures are particularly needed in optical systems such as ultra precise optical clocks, as well as materials with excellent dimensional stability and light weight properties for space applications such as telescopes, optical benches, and optical resonators. Also, the dimensional stability of mounting technologies of materials with different properties is of high interest for such applications. Glass ceramics and composite materials can be tuned to reach a very low coefficient of thermal expansion (CTE) at different temperatures, enabling best stability in the operating temperature for certain applications. In order to determine the CTE of such highly stable materials, very accurate set-ups are needed. In this thesis, metrology set-ups to measure the CTE of a large variety of material samples are designed, realized and verified, measuring dimensionally stable glass ceramics. The set-ups are able to characterize tube shaped samples at a temperature range of 140 K to 333 K. Due to our unique mirror mount design all kind of materials can be characterized. The optical dilatometer set-ups are based on a heterodyne interferometer with a displacement sensitivity at the sub-nanometer level. This instrument is used to measure the expansion of a sample when applying controlled small amplitude temperature signals. A carbon fiber reinforced polymer (CFRP) sample was characterized where CTE levels of 10 -8 K -1 from 140 K to 250 K were measured and a detailed uncertainty analysis was performed. The verified metrology set-up for tube shaped samples was adapted for CTE measurements of larger structures. Therefore, a large thermal chamber was set up and a 0.5 m CFRP spacer with Zerodur endfittings as a representative joint technology demonstrator for the GRACE Follow-On space mission at 302 K was investigated.
Subjects
dilatometer

; 

dilatometry

; 

interferometer

; 

CTE

; 

coefficient of thermal expansion

; 

glass ceramics

; 

CFRP

; 

carbon fiber reinforced polymer

; 

heterodyne interferometer

; 

laser interferometry

; 

dimensional stability

; 

space applications

; 

low temperature

; 

ambient temperature

; 

room temperature

; 

wide temperature range
Institution
Universität Bremen
Faculty
Fachbereich 04: Produktionstechnik, Maschinenbau & Verfahrenstechnik (FB 04)
Type
Dissertation
Secondary publication
No
Language
English
File(s)
Loading...
Thumbnail Image
Download
Name

00106113-1.pdf

Size

17.82 MB

Format

Adobe PDF

Checksum

(MD5):4c9f7ea9fdfb3b84413f732ff0e5af54

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Accessibility settings
  • Privacy policy
  • End User Agreement
  • Send Feedback