Bardenhagen, Ingo
Loading...
Preferred name
Bardenhagen, Ingo
Official Name
Bardenhagen, Ingo
2 results
Now showing 1 - 2 of 2
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Kohlenstoff Xerogele als Kathodenmaterial für die aprotische Lithium/Sauerstoff Batterie : Einfluss der Porenstruktur auf die physikalischen und elektrochemischen Eigenschaften(2015-11-17); ; ; In this work the influence of the pore structure of the GDE on the discharge reaction od the aprotic Lithium-oxygen battery has been investigated. Therefore, carbon xerogels with different pore sizes were synthesized and analyzed by nitrogen adsorption. The samples with the highest and lowest mesopore size have been chosen to investigate the wetting behavior of solvents on the pore walls. Nuclear magnetic resonance (NMR) measurements were conducted to resolve the liquid phase inside of the porous structure. To use the carbon xerogels as active material in the GDE they were directly synthesized in a carbon fiber paper. The resulting ready-to-use and binder-free cathodes were discharged in the lithium/oxygen system and the deposition of discharge products was investigated. Electrochemical impedance measurements were conducted to observe the changes at the cathode during discharge revealing that the charge transfer between the carbon surface and the oxygen stays nearly constant. On the other hand it was also found that the pore clogging with discharge product and consequently the hindered oxygen diffusion are the limiting processes in this type of GDE.doctoral thesis386 167 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, On the suppression of background signals originating from NMR hardware components. Application to zero echo time imaging and relaxation time analysisModern NMR imaging systems used for biomedical research are equipped with B0 gradient systems with strong maximum gradient strength and short switching time enabling (1)H NMR measurements of samples with very short transverse relaxation times. However, background signal originating from non-optimized RF coils may hamper experiments with ultrashort delays between RF excitation and signal reception. We demonstrate that two simple means, outer volume suppression and the use of shaped B0 fields produced by higher-order shim coils, allow a considerable suppression of disturbing background signals. Thus, the quality of NMR images acquired at ultrashort or zero echo time is improved and systematic errors in quantitative data evaluation are avoided. Fields of application comprise MRI with ultrashort echo time or relaxation time analysis, for both biomedical research and characterizing porous media filled with liquids or gases.journal article114 109
