Eifler, Dietmar
Loading...
Preferred name
Eifler, Dietmar
Official Name
Eifler, Dietmar
2 results
Now showing 1 - 2 of 2
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Einfluss von Wasserstoff und nichtmetallischen Einschlüssen auf die Versagensmechanismen des Wälzlagerstahles 100Cr6 im VHCF-Bereich(2015-12-07); ; ; The fatigue life of the bearing steel 52100 (100Cr6) in bainite and martensite conditions was investigated up to 2 x 109 cycles. The tests were performed under cycling tension (R = 0.1) and tension compression (R = -1) on a piezo-electric ultrasonic testing equipment. The specimens are designed with a cylindrical part in the highly stressed centre. Due to grinding, compressive residual stresses are found at the surface, hence crack initiation solely occurs subsurface. Prior testing half of the specimens was charged with hydrogen. The hydrogen content varies from 0.6 as initial condition to 3 ppm after charging. With increased hydrogen content the endurance limit decreased to nearly half of the value of uncharged conditions and crack initiation sites changed: Conditions with low hydrogen content failed from chromium carbides, titanium nitrides or slag agglomerations. Conditions with 3 ppm hydrogen failed from slag agglomerations, often in combination with aluminium magnesium oxides, and manganese sulphides. Next to the inclusions a fine granular area (FGA) could be observed in some cases, and nearly all fractured surfaces showed a fisheye surrounded by an Optically Bright Zone (OBZ) with the crack initiating inclusion in its centre. Furthermore, selected specimens where analysed using secondary ion mass spectroscopy in a time of flight setup (ToF-SIMS) to ascertain the local hydrogen content. From the results it is assumed that hydrogen accumulates in the cavity at inclusions or bonds to the inclusion if it contains silicon.doctoral thesis616 306 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Überrollungslebensdauer des Wälzlagerstahls100Cr6 in Abhängigkeit von nicht idealenGefügeausbildungen unter besondererBerücksichtigung der Karbidzeiligkeit(2009-12-04); ; ; In this study rolling contact fatigue life tests of different variants of 100Cr6 (SAE 52100) bearing steel were performed with roller bearings under hydrodynamic lubrication. All bearings failed from subsurface crack initiation. Additionally determined fatigue lives gained from compression torsion tests with round specimens could be correlated with the results of the rolling contact fatigue tests. Carbide strings resulting from primary carbides are locally concentrated in the core of the semi-finished material where the non-metallic inclusion content is also increased. Generally, carbide strings may have a negative influence on the fatigue life behaviour. If present in regions of highly stressed material in the bearings oxides are the life limiting factor of rolling contact fatigue life.doctoral thesis469 2092
