Reinschluessel, Anke Verena
Loading...
Preferred name
Reinschluessel, Anke Verena
Official Name
Reinschluessel, Anke Verena
Alternative Name
Reinschluessel, Anke V.
Reinschluessel, Anke
ORCID
6 results
Now showing 1 - 6 of 6
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, Put That Needle There: Customized Flexible On-Body Thin-Film Displays for Medical Navigation(ACM, 2020-05-30); ; ; ; Informed by modern imaging techniques, current medical navigation systems support physicians during a variety of interventions, such as needle-based operations. During these, an abundance of information is often displayed on monitors placed in positions that are uncomfortable for the operator to view. In this article, we address these issues with the concept and prototype of a customized flexible display that is placed on the patient’s body to provide the essential information at just the right location. We present an empirical evaluation comparing the flexible display against a control condition using a standard interventional monitor setup and an additional condition that combines both. Our results show that the flexible display significantly reduces task load while improving overall usability. Furthermore, we found indications that the flexible display reduces task completion time while also observing a negative effect on accuracy, which needs to be balanced carefully.journal articleBand:1Heft:3154 88 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, An Interactive-Shoe For Surgeons: Hand-Free Interaction With Medical 2D Data(2018-04-20); ; ; ; During interventions, surgeons often need to review medical imaging data, e.g., CT scans. Usually, surgeons need to rely on an assistant to browse the images because of sterility requirements. Communication with a substitute operator is tedious and error-prone if the operator does not have an equal level of professional experience and might interrupt the workflow. We present a sensor-integrated shoe allowing surgeons to browse and manipulate 2D medical image data by foot movement. It is portable and wearable. The shoe uses an optical sensor taken from an off-the-shelf computer mouse for tracking the foot movements and an additional micro-switch to turn it on or off. We evaluated the performance of the shoe interface against a control condition with assistant together with ten surgeons in an empirical user study. Our results provide first indications for the effectiveness of a shoe interface in this application area.conference paper124 153 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Auditory Display for Telerobotic Transnasal Surgery Using a Continuum Robot(World Scientific Publishing Co Pte Ltd, 2019-05-16); ; ; ; Tubular continuum robots can follow complex curvilinear paths to reach restricted areas within the body. Using teleoperation, these robots can help minimize incisions and reduce trauma. However, drawbacks include the lack of haptic feedback and a limited view of the situs, often due to camera occlusion. This work presents novel auditory display to enhance interaction with such continuum robots to increase accuracy and path-following efficiency and reduce cognitive workload. We recreate a typical use case with a test environment that simulates a transnasal intervention through the sphenoidal sinus including a simulated continuum robot. Distance information is mapped to changes in a real-time audio synthesizer using sung voice to provide navigation cues. User studies with novice participants and clinicians were performed to evaluate the effects of auditory display on accuracy, task time, path following efficiency, subjective workload, and usability. When using auditory display, participants exhibit significant increase in accuracy, efficiency, and task time compared to visual-only display. Auditory display reduced subjective workload and raised usefulness and satisfaction ratings. The addition of auditory display for augmenting interaction with a teleoperated continuum robot has shown to benefit performance as well as usability. The method could benefit other scenarios in navigated surgery to increase accuracy and reduce workload.journal articleBand:4Heft:2109 152 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Vibro-Band: Supporting Needle Placement for Physicians with VibrationsMedical images and navigation systems support physicians during needle-based interventions. As the information is primarily displayed on monitors, the physician's attention is drawn away from the patient's body. To address this issue, we explore the additional use of a vibration wristband that directs the movements for needle-based operations via different vibration patterns on the operator's arm. We conducted a first user study comparing the combination of tactile and visual guidance versus visual-only feedback with 12 participants to investigate the general feasibility. Our results show that task times, usability scores, cognitive load, and accuracy are comparable for both conditions suggesting that vibration feedback is generally suitable for medical navigation tasks and warranting further iteration and research in this direction.conference paper93 128 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Empowering surgeons - a multimodal interaction approach to improve computer-assisted surgical planning and interventions(2022-06-17); ; ; Advancements like X-ray, magnetic resonance imaging (MRI), computer tomography (CT), and infrared needle tracking improved diagnostics and raised survival rates in the medical field. These computer support systems are an integral part of contemporary treatment. Technological advancements such as 3D visualisations, virtual reality and similar technologies improved work-life in many areas, e.g., architecture, the film industry or specialised training for pilots. In contrast, medical staff still uses "rudimentary" devices such as a desktop PC with a mouse and keyboard to interact with the 2D images from scans. Technologies with high usability and user experience are sparse. The prototypes presented in this thesis focus on empowering surgeons by improving the interaction with medical data and supporting procedures in the preoperative and intraoperative setting. In the scope of the research presented in this thesis, I introduce surgeons to tangibles, 3D models, virtual reality, gesture control, electroluminescence displays and new kinds of navigational feedback. In combination with methods from human-computer interaction, such as user-centred and participatory design, focus groups as well as user studies, I integrate these technologies into applications to empower surgeons rather than restrict or replace them. Overall, the research presented in this thesis advocates using a human-computer interaction point of view and methods to resolve current technology-based issues in the medical domain. The research results show that these methods and approaches achieved better usability and user experience without increasing the perceived workload. The presented prototypes also increase the surgeons' autonomy and thereby provide empowerment to the surgeons.doctoral thesis668 341 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Virtual Reality for User-Centered Design and Evaluation of Touch-free Interaction Techniques for Navigating Medical Images in the Operating Room(2017-05-06); ; ; ; Computer-assisted surgery has pervaded the operating room (OR). While display and imaging technologies advance rapidly, keyboard and mouse are still the dominant input devices, even though they cause sterility problems. We present an interactive virtual operating room (IVOR), intended as a tool to develop and study interaction methods for the OR, and two novel touch-free interaction techniques using hand and foot gestures. All was developed and evaluated with 20 surgeons. The results show that our techniques can be used with minimal learning time and no significant differences regarding completion time and usability compared to the control condition relying on verbal instruction of an assistant. Furthermore, IVOR as a tool was well received by the surgeons, although they had no prior experience with virtual reality. This confirms IVOR is an effective tool for user-centered design and evaluation, providing a portable, yet realistic substitution for a real OR for early evaluations.conference paper124 201
