Item type:Publication, Optical Metrology Terminal for Satellite-to-Satellite Laser Ranging(2022-01-24); ; ; Interferometric laser ranging is a powerful enabling technology for high-precision satellite-to-satellite tracking within the context of Earth observation, gravitational wave detection, and formation flying. Since the launch of the gravity field mission GRACE Follow-On in 2018, the onboard Laser Ranging Interferometer has successfully been operating as a technology demonstrator in a low-Earth orbit and has significantly enhanced the measurement accuracy compared to the former microwave instrument. Within the framework of this work, a new design concept for an optical instrument of this type is derived, allowing the location of the reference point and the external beam offset to be tuned independently of the integrated retroreflector. On this basis, optical design and construction of the "Optical Metrology Terminal" are carried out, resulting in a basically flight-representative instrument as it could be used in future gravity field missions. Experimental evaluation on elegant breadboard level demonstrated excellent tolerance against variations of the angle of incidence.doctoral thesis356 661 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Enabling ultra-high vacuum for quantum optical instruments in space(2025-07-02); ; Clouds of ultra-cold atoms or a Bose-Einstein Condensate (BEC), perhaps borne in microgravity, can be used as test objects for high-precision matter wave interferometers. Quantum optical instruments based on this technology have the potential to validate scientific theories, such as the unification of the standard model and general relativity, or to measure inertial forces for advanced navigation of vehicles. The point-like nature of a BEC and the unlimited time of free-fall in space increase the achievable accuracy of matter wave interferometers. Any disturbance of the ultracold atoms can trigger the interferometer to lose precision. Following, Ultra-High Vacuum (UHV) is fundamental to achieve a BEC and perform high-precision matter wave interferometry. The hits with the background gas in the vacuum system result in impulse changes and thereby a loss rate, which in turn causes loss of interferometer contrast. In the scope of this thesis, various key technologies for ultra-cold atom UHV systems in space are investigated, simulated, and tested. The advantages and disadvantages of pump systems and their usage in cold atom instruments are shown. A focus is set on the lifetime verification for filaments of a Titanium Sublimation Pump (TiSub) and the optimization of gas species dependent pumping. Numerical analysis of the filament degradation is used to configure a TiSub for long-term missions. Usually, the limiting factor for pump rates is, in the regime of molecular flow, the transmission probability and conduction of appliances. Simulation work with a Test Particle Monte-Carlo (TPMC) method is performed to gather detailed information on transmission probabilities for in-vacuum components. Several geometries and their dimensions were modified and analyzed. The optimal parameters for meshes, sintered filters, atom chip holders, and a Differential Pumping Stage (DPS) were found to maximize the effective pump rate. Experimental setups were developed to verify and validate important parameters of UHV systems. An outgassing rate measurement testbed is built, characterized, and used for the measurement of assemblies and materials. Here, challenges of the measurement setup are tackled and elaborated. Material specific outgassing rates were measured and are in good agreement to literature values. First assembly measurements showed a significant influence of heat and driving currents on the outgassing rate. Three laboratory setups were developed, to investigate on thermal, dynamic mechanical, and corrosive properties for all-metal seals of UHV windows. Results show the leakage rate of Indium (In), Lead (Pb), Gold (Au), and glue sealed windows. For leak tight connections, the leakage rate was investigated for various material combinations and surface qualities under representative dynamic mechanical and thermal loads — with no significant increase for In, Pb, and glue as seal. With another test setup ovens for alkali metal evaporation were characterized by their partial pressure and temperature behaviour. Results showed clearly that a valve is perfect to enable an immediate alkali metal partial pressure shut down. On the other hand, thermal ovens with cracked ampule and no valve were not suitable to completely shut down the alkali metal pressure, and in addition, needed longer activation times. In experiments using cracked ampules, the long times to establish a high partial pressure were probably caused by the disadvantageous heat transport and transmission of the alkali metal through the cracked glass. The measurements for filled, valve-regulated, and cracked ovens point out that there is no systematic root cause for the delay. The laboratory setups and simulation results were used to develop the International Space Station (ISS) payload Bose-Einstein-Condensate and Cold Atom Laboratory (BECCAL) and especially the UHV system for this space instrument. An overview of BECCAL and the UHV system in detail is given. Here, the ISS as platform, the goals of BECCAL, and the payload setup are shown. Finally, the pressure distribution of the UHV system were analyzed and simulated. With new methods and numerical simulations, investigations of pressure differences in the vacuum system are performed and thus help to verify scientific data and validate requirements. The analysis proves that the requirement of < 1 × 10−8 Pa (< 1 × 10−10 hPa) at the location of ultra-cold atoms can be achieved. In a prototype setup, the validity of the analysis is shown. The results of this thesis lay the groundwork for the development and optimization of future UHV systems in space dedicated for quantum optical instruments.doctoral thesis88 80 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Laser-interferometric dilatometry(2017-10-04); ; ; Highly dimensionally stable materials and structures are particularly needed in optical systems such as ultra precise optical clocks, as well as materials with excellent dimensional stability and light weight properties for space applications such as telescopes, optical benches, and optical resonators. Also, the dimensional stability of mounting technologies of materials with different properties is of high interest for such applications. Glass ceramics and composite materials can be tuned to reach a very low coefficient of thermal expansion (CTE) at different temperatures, enabling best stability in the operating temperature for certain applications. In order to determine the CTE of such highly stable materials, very accurate set-ups are needed. In this thesis, metrology set-ups to measure the CTE of a large variety of material samples are designed, realized and verified, measuring dimensionally stable glass ceramics. The set-ups are able to characterize tube shaped samples at a temperature range of 140 K to 333 K. Due to our unique mirror mount design all kind of materials can be characterized. The optical dilatometer set-ups are based on a heterodyne interferometer with a displacement sensitivity at the sub-nanometer level. This instrument is used to measure the expansion of a sample when applying controlled small amplitude temperature signals. A carbon fiber reinforced polymer (CFRP) sample was characterized where CTE levels of 10 -8 K -1 from 140 K to 250 K were measured and a detailed uncertainty analysis was performed. The verified metrology set-up for tube shaped samples was adapted for CTE measurements of larger structures. Therefore, a large thermal chamber was set up and a 0.5 m CFRP spacer with Zerodur endfittings as a representative joint technology demonstrator for the GRACE Follow-On space mission at 302 K was investigated.doctoral thesis434 229 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Ultra-High Vacuum Systems for Experiments with Cold Atoms in Space(2023-06-06); ; ; Dual-species atom interferometry, with Bose-Einstein condensates, is a promising technique for ultra-precise and accurate measurements for spaceborne applications, such as inertial sensing, future detection of gravitational waves, earth observation, and testing fundamental physics. An ultracold atom experiment on a future satellite mission could improve the precision of testing general relativity, with the test of the universality of free fall. The technology discovery of such a complex and challenging experiment, requires a multitude of space qualified technologies and developments. The MAIUS-2/3 (Matter-Wave Interferometry Under Microgravity) missions, within the QUANTUS (Quantum Gases in Microgravity) consortium, aims to perform the first dual-species atom interferometer with ultracold rubidium and potassium atoms on a sounding rocket. It is used as a pathfinder mission to further develop the technologies which enable future cold atom missions. Space suitable ultra-high vacuum (UHV) systems are one of the enabling technologies for missions on long-duration microgravity platforms, such as the International Space Station or a satellite. The scientific payload MAIUS-B, flying on both missions MAIUS-2 and MAIUS-3, is introduced in this thesis. The payload is sheltered within seven RADAX (radial-axial) hull segments, and is divided into five subsystems; electronics, physics package, laser system, laser electronics, and batteries. The newly developed thermal control system and ground support equipment is capable of accounting for an internally produced heat load of 707.6 W and a temperature rise by aerodynamic drag during launch. The mass and size was continuously optimized, with a final mass of 335.3 kg and a length of 2.8 m, which is within the limits of 340.0 kg and 3.0 m. A load assessment of the new suspension system showed that the payload is capable of carrying the MAIUS-B payload up to 981ms^(−2) (100 g0) within a reasonable safety margin. A new umbilical and sealing concept was implemented, providing the payload until lift-off with power, data, and cooling liquid connections. The UHV system was redesigned to fit within the mass and size requirements. Two titanium sublimation pumps and one ion getter pump are maintaining a pressure of 2 × 10^(−11) hPa. This is one order of magnitude better than the experiment required pressure of 5 × 10^(−10) hPa. Several vacuum components, such as the differential pumping stage, the oven design, and the pumps itself, were modified or redesigned. The physics package, including the UHV system, was qualified for a vibration level of 19.6ms^(−2) RMS (2.0g0RMS), compared to the maximum flight level of 17.7ms^(−2) RMS (1.8 g0RMS) throughout a sounding rocket mission. The UHV system is capable of regaining the required pressure within 19 s. To investigate the influence of static loads on the leakage rate of ConFlat (CF) seals, a test setup was built. The tests were performed to indicate the influence on the tightening torque (10Nm, 12.5Nm, 15Nm), the flange material (aluminum [AluVaC®], stainless steel [316LN-ESR, 14429-ESU]), and different oxygen free high conductivity (OFHC) copper gaskets (annealed, non-annealed). The presented results provide the first data set on the leakage rate for CF DN40 flange connections tested up to a applied force of 1 950N.doctoral thesis642 419