    Item type:Publication,
    Robust and time-effcient determination of perfusion parameters using time-encoded Arterial Spin Labeling MRI
    In clinical routine, arterial spin labeling (ASL) faces many challenges, such as time pressure, patient- and disease-specific artifacts, e.g., in steno-occlusive and Moya-Moya disease. In addition, individually tailored parametrization of the MR pulse-sequence is frequently required. Time-encoded ASL-techniques like Hadamard time-encoded pseudocontinuous ASL (H-pCASL) offers a time and signal efficient way to measure accurately both perfusion and arterial transit-times. However, it relies on the decoding of a series of volumes. If even a single volume is corrupted this might, via the decoding process, lead to artifacts in the entire dataset and in the worst case result in the loss of the data. In this thesis a general introduction to time encoded ASL is given and three methods are introduced to increase the robustness of time-encoded ASL against image artifacts and to detect corrupted images. The first method is Walsh-ordered time-encoded H-pCASL (WH-pCASL). It proposes the Walsh-ordering of Hadamard encoding-matrices. In contrast to conventional H-pCASL, this makes perfusion-weighted images accessible during a running experiment and even from incomplete sets of encoded images. An optional additional averaging strategy is based on a mirrored matrix and results in more perfusion-weighted images without any penalty in time. The feasibility of the method is shown using five volunteer datasets. As a second method non-decoded time-encoded ASL is introduced. This novel model-based approach to quantification avoids the decoding step altogether. It models the non-decoded time encoded signal. Therefore it uses the convolution of the tissue response function with a model of the true encoded arterial input function, which is determined by the employed encoding matrix. The model was implemented in a Bayesian model-based ASL analysis framework to fit maps for hemodynamic parameters. The feasibility of the method is demonstrated in a study with five volunteers. The last method is an algorithm for the automated detection of outliers and corrupted images, which is based on variational Bayesian inference (VB). Using the variance of the posterior normal distributions, the algorithm measures the quality of a fit directly and without the need for a separate reference dataset. Its performance and feasibility is demonstrated using volunteer data and a clinical dataset.
    doctoral thesis
      752  222
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Robust Arterial Spin Labeling T2 Measurements
    Perfusion and bolus arrival time are often quantified physiological parameters. By additionally quantifying permeability it is hoped to better understand tissue physiology or monitor small permeability changes in cerebrovascular diseases, which are difficult to detect by traditional gadolinium contrast agents. A problem of gadolinium contrast agents is the size of the macro molecules. They cannot pass an intact or slightly damaged blood brain barrier, whereas hydrogen molecules are small enough to pass it. In arterial spin labeling (ASL) the hydrogen spins of the water molecules in inflowing blood are selectively inverted and can be used as a non-invasive endogenous contrast agent. In standard ASL modules, generally only T1 effects are considered. This is sufficient for perfusion and arrival time but not for capillary wall permeability quantification, due to the small difference of blood and tissue T1 times. In contrast to this, T2 times of blood and tissue are considerably different, which makes arterial spin labeling T2 measurements a potential method for permeability estimations if current modules are extended and optimized to include T2. Yet, accurate T2 calculations are often very time consuming, limiting the acquisition for an individual patient and the general implementation in clinical routine. In the present work, acquisition techniques and fitting routines of a multi-TI multi-TE 3D-GRASE (gradient and spin echo) sequence are presented allowing a fast and reliable T2 calculation at every inflow time, which can be used for permeability estimations. An optimized acquisition scheme and T2 calculation algorithm is found with regard to accuracy, measurement time, and signal-to-noise ratio (SNR). The concept of adaptive averaging is presented, which allows the acquisition of longer inflow times more often than shorter ones, improving SNR at long inflow times by 1.5 and more, but by simultaneously keeping the total scan time constant. The impact on T2 calculations from stimulated echoes in combination with different kinds of crusher gradients at several refocusing flip angles is evaluated in phantoms and volunteers. The fitted T2 results are compared to simulations and gold standard single spin echo T2 values. Finally, T2 values at multiple inflow times with different turbo factors (TF) are obtained. The impact of the turbo factor on the T2 calculation is simulated and verified in a volunteer study, resulting in a suggestion for an optimised imaging scheme for TF>1. For TF1 the multi-TE ASL 3D-GRASE sequence is already capable of T2 measurements at multiple inflow times, very close to T2 values obtained with the gold standard single spin echo sequence. The T2 values could be directly incorporated in a two compartment model for perfusion quantification, to further study tissue functions or disease related to permeability changes.
    doctoral thesis
      399  165
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Acquisition and processing techniques for rapid, robust, and patient-specific measurement of cerebral diffusion and perfusion using Magnetic Resonance Imaging
    Magnetic resonance imaging (MRI) is a powerful technique that enables accurate medical diagnoses. Not only does it allow the visualization of static tissue contrasts, but it also provides the ability to measure the function and physiology behind important life processes. This dissertation presents two methods for imaging physiological effects, namely diffusion and perfusion. For diffusion-weighted imaging, but not limited to this application, a technique called simultaneous multi-contrast (SMC) imaging is introduced to acquire multiple image contrasts from different scan types within a single measurement. This technique offers new opportunities in clinical protocols where examination time is a critical factor and multiple image contrasts need to be acquired. The method was tested in a phantom and healthy subjects. The results showed that simultaneous acquisition of two contrasts (here diffusion-weighted imaging and T2*-weighting) with SMC imaging is possible with robust contrast separation and minimal impact on image quality. Thereby, the simultaneous acquisition of multiple contrasts reduces the overall examination time and there is inherent registration between contrasts. For cerebral perfusion-weighted imaging, the goal of this work was to increase the robustness of time-encoded arterial spin labeling (ASL) to image artifacts by adjusting the timing of imaging during active scanning individually for each subject. One of the major challenges in ASL imaging is the high variability of arterial transit times (ATT), which leads to arterial transit delay (ATD) artifacts. In particular, in patients with pathologic changes, these artifacts occur when post-labeling delay (PLD) and bolus duration are not optimally matched to the individual, resulting in difficult quantification of cerebral blood flow (CBF) and ATT. This is also true for the free-lunch (FL) approach in Hadamard-encoded pseudocontinuous ASL (H-pCASL). The method was tested in healthy subjects, with FL-bolus timing individualized by the developed and implemented adaptive H-pCASL sequence in combination with an automatic feedback algorithm. Automatic subject-specific adjustment of the FL-bolus PLD during an ongoing measurement may reduce uncertainties in perfusion quantification and reduce the number of cases in which measurements have to be repeated because the recommended timing does not fit the patient.
    doctoral thesis
      372  223