Now showing 1 - 2 of 2
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Vision threads: a novel approach to generic camera calibration
    (Society of Photo‑Optical Instrumentation Engineers (SPIE), 2021-06-20) ; ;
    Optical metrology techniques such as fringe projection technology and phase-measuring deflectometry, which use cameras as image sensors for 3D coordinate measurement and inspection, are becoming increasingly demanding. The necessary precise and at the same time robust calibration of image sensors of these systems is offered by so called vision ray calibration. This generic approach is a model-free description of a vision ray and are determined for each imaging sensor pixel. Numerous images of the sinusoidal fringe images displayed on the active calibration target (LCD) are captured in different poses. This generates a large amount of data and consequently leads to time-consuming evaluation for the camera calibration. In this paper, we propose a new optimization method that uses “vision threads" instead of vision rays to enhance the computation efficiency associated with conventional vision ray calibration. We present MATLAB simulation results in to validate our novel approach.
    conference paper
      37  46
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Qualification of holistic and generic camera-system calibration by fringe projection
    (Society of Photo‑Optical Instrumentation Engineers (SPIE), 2021-06-20) ; ;
    Vision Ray Calibration provides a description of imaging properties of cameras by identification of an independent vision ray for each sensor pixel. Due to this approach, no model parameters of any cameras are determined in the non-linear optimization procedure of the calibration. Therefore, a setup of multiple cameras can be considered as one imaging system. This enables simultaneous and holistic calibration of an arbitrary number of cameras. Vision Ray Calibration utilizes Liquid Crystal Displays as calibration targets since these can provide the required continuous spatial coding of their surfaces by means of Phase Shifting Technique. However, displays employed as calibration targets exhibit some unfavorable properties such as flatness deviations of the surface. It is known that extending the Vision Ray Calibration by a polynomial parameterization of the display surface increases the calibration accuracy. This work investigates the influence of the order of polynomial terms employed for display surface parameterization. The stereoscopic Fringe Projection enables the evaluation of the calibration accuracy since Vision Ray Calibration of a stereo camera setup provides full system calibration for this technique. Our results confirm the significant improvement of calibration accuracy due to parameterization of flatness deviations of the display. Best calibration results were obtained by limiting the maximum order of polynomial terms to three. Our results indicate that terms of higher orders do not contribute true surface shape features.
    conference paper
      30  30