Now showing 1 - 8 of 8
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Security concept for gateway integrity protection within German smart grids
    In order to meet future challenges of energy grids, secure communication between involved control systems is necessary. Therefore, the German Federal Office for Information Security (BSI) has been published security standards concerning a secure communication unit for smart metering systems, which is named Smart Meter Gateway (SMGW). This present security concept of this paper takes these standards into consideration, but extends their level of information security by integrating elements from the Trusted Computing approach. A tamper-resistant grid has been integrated with chosen hardware modules and a trustworthy boot process has been applied. To measure and evaluate the SMGW’s integrity continuously the specification Trusted Network Connect (TNC) from the Trusted Computing Group (TCG) has been used furthermore. This work is an outcome of the German research project SPIDER from BMWi, which started in March 2013 and will end in February 2015.
    conference paper
      114
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Custom Transport Interface for the Integration of Trusted Network Connect in German Smart Metering Systems
    The integration of Trusted Network Connect (TNC) enhances the overall security of the German Smart Metering System. For that reason, the research project SPIDER has described a concept to integrate TNC into the German Smart Metering System. However, the project has discovered contradictions between the standards, which are defined for the German Smart Metering System and the standards that describe TNC regarding the protocols for the transmission of data. This paper describes and analyzes the different disagreeing standards and evaluates different approaches to overcome these contradictions by reusing existing protocols for the transmission of TNC data in compliance with the standards regarding the German Smart Metering System.
    conference paper
      115
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Sicherheitskonzept zum Schutz der Gateway-Integrität in Smart Grids
    Um den Herausforderungen zukünftiger Energienetze begegnen zu können, ist eine sichere Datenübertragung zwischen den Steuerkomponenten notwendig. Das Bundesamt für Sicherheit in der Informationstechnik (BSI) hat hierfür Sicherheitsvorgaben in Bezug auf eine zentrale Kommunikationseinheit, das sog. Smart Meter Gateway, (SMGW) entwickelt. Das Sicherheitskonzept berücksichtigt diese Vorgaben und erhöht zusätzlich die Informationssicherheit des SMGW indem es Elemente des Trusted Computings (TC)-Ansatzes integriert. Dazu wird ein Tamper-Resistant-Grid über ausgewählte Hardwareelemente gelegt, das Secure Boot-Verfahren angewendet und eine laufende Integritätsmessung des SMGWs über den Trusted Network Connect (TNC) - Ansatz realisiert.
    conference paper
      108
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Moderne Energieverteilnetze: Bedrohungen und GegenmaĂźnahmen
    Das traditionelle deutsche Stromnetz befindet sich im Wandel. Intelligente, vernetzte Steuerungssysteme sollen traditionelle, lokale Steuerungssysteme ersetzen, um verschiedene Herausforderungen in der Netzsteuerung zu kompensieren. Hieraus entstehen neue Anforderungen an die Informationssicherheit von Energieverteilnetzen. Im Forschungsprojekt „Systemsicherheit von Energieversorgungsnetzen bei Einbindung von Informations- und Kommunikationstechnologien“ (SEnCom) wurde deshalb die Informationssicherheit in Energieverteilnetzen der nahen Zukunft untersucht, um mögliche Defizite aufzudecken und Gegenmaßnahmen zu erarbeiten. Diese Veröffentlichung stellt eine Bedrohungsanalyse für dezentrale Standorte in Energieverteilnetzen vor und gibt den Stand der Technik hinsichtlich der Informationssicherheit mit Hilfe bestehender Standards wieder. Auf dieser Basis werden ausgewählte Gegenmaßnahmen für entdeckte Bedrohungen erläutert. Energienetzakteure sollen ermutigt werden, proaktiver mit dem Thema der Informationssicherheit umzugehen.
    conference paper
      89
  • Some of the metrics are blocked by your 
    Item type:Publication,
    IT-Security for Smart Grids in Germany: Threats, Countermeasures and Perspectives
    The sustainable energy transition is one of the most ambitious projects in Germany. Its progress and challenges are observed by many other countries. In that regard, latest research activities emphasise innovative concepts and technologies for energy distribution grids. Under the general term smart grid, intelligent control mechanisms are needed to cope with arising challenges of volatile and decentralised renewable energy resources. This creates new security threats for the critical energy supply infrastructure. T raditionally, energy production and distribution has been part of a centralised and closed system. Today, renewable energy resources are decentralised and interconnected to virtual power plants using shared networks, such as the internet. The so called "air gap" has been closed. For the most part, energy distribution grids do no longer rely on physical and local measures for control and stabilisation; they have become more dynamic and centrally controlled instead. Furthermore, established proprietary and energy specific systems are replaced by standard IT protocols and commercial-of-the-shelf hardware. This development raises further security concerns. Known threats from the office IT are applicable to industrial control systems (ICS), now. The research project SEnCom (System security of energy distribution grids with integrated information and communication technologies) addresses these concerns and examines the nearby future to discover emerging IT security threats in German energy distribution grids. While traditional and centralised control systems are considered to be relatively secure, this paper will introduce findings based on a threat model for decentralised locations in an energy distribution grid. These results reveal particular weaknesses regarding the topics monitoring and integrity protection of ICS in the German energy sector. In addition, an insight into the current state of the art for the protection of ICS and an introduction of countermeasures (e. g Trusted Computing) to discovered weaknesses, in energy distribution grids, is provided. In conclusion, the paper wants to encourage energy distribution operators and ICS vendors to be more proactive in terms of IT security, because if not, the energy distribution grid may become a vulnerable target for hacking attacks (e. g. cyber terrorism) in the future.
    conference paper
      119
  • Some of the metrics are blocked by your 
    Item type:Publication,
      117
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Integration von TNC in ein deutsches Smart Meter Gateway
    Durch die gesetzliche Einführung intelligenter Messsysteme sollen das Messwesen für das Energienetz und der Umgang mit Energie in Deutschland verbessert werden. Das Bundesamt für Sicherheit in der Informationstechnik (BSI) hat, nach dem Prinzip „Secure by Design“, hierfür Sicherheitsrichtlinien in Bezug auf eine zentrale Kommunikationseinheit, das sogenannte Smart Meter Gateway (SMGW), entwickelt. In dem Forschungsprojekt SPIDER wurden diese Richtlinien untersucht. Hierbei wurde Trusted Network Connect (TNC) als zusätzlicher Sicherheitsbaustein in einem erweiterten Sicherheitskonzept erkannt, der die Sicherheit eines SMGW und damit eines intelligenten Messsystems erhöhen kann. Diese Veröffentlichung baut auf bereits bestehenden Veröffentlichungen zu dem genannten Sicherheitskonzept aus dem Forschungsprojekt SPIDER auf und stellt eine erfolgreiche Integration von TNC in ein SMGW auf der Basis des Sicherheitskonzepts vor.
    conference paper
      130
  • Some of the metrics are blocked by your 
    Item type:Publication,
    Absicherung von Smart-Meter-Umgebungen mit Trusted Computing
    Die sichere Datenübertragung zwischen den Steuerkomponenten zukünftiger, intelligenter Energienetze ist zwingend notwendig, um die Anforderungen an die Stabilität und Sicherheit erfüllen zu können. Hierfür wurden Sicherheitsvorgaben von dem Bundesamt für Sicherheit in der Informationstechnik (BSI) in Bezug auf eine zentrale Kommunikationseinheit zur Sicherung intelligenter Energienetze, das sog. Smart Meter Gateway (SMGW), entwickelt. Das SPIDER-Projekt des BMWi berücksichtigt diese Vorgaben bei der Entwicklung ihres SMGW und erhöht den Integritätsschutz, indem es Elemente aus dem Ansatz Trusted Computing (TC) von der Trusted Computing Group (TCG) integriert. Aufbauend auf Trusted Boot wird ein Secure-Boot-Verfahren angewendet und eine laufende Integritätsmessung über die Trusted Network Connect (TNC) Architektur realisiert. Dadurch ist die Integrität eines SMGW aus der Ferne erkenn- und kontrollierbar. Man muss sich daher nicht mehr nur auf die durch das BSI vorgeschriebene Verplombung des Gehäuses verlassen. Dieser Ansatz geht damit einen Schritt weiter, als die bisherige BSI-Spezifikationen es vorsehen.
    conference paper
      126