Vellekoop, Michael
Loading...
Preferred name
Vellekoop, Michael
Official Name
Vellekoop, Michael
Alternative Name
Vellekoop, M.
Vellekoop, M. J.
Vellekoop, Michael J.
Vellekoop, Michael Johannes
Vellekoop, Michel
Main Affiliation
ORCID
GND
3 results
Now showing 1 - 3 of 3
- Some of the metrics are blocked by yourconsent settings
Item type:Publication, A microsystem for on-chip droplet storage and processing(2020-09-10); ; ; Die Tropfen-Mikrofluidik ist ein nützliches Verfahren, mit dem biologische und chemische Experimente mit hoher Geschwindigkeit und verbesserter Effizienz durchgeführt werden können. Viele Anwendungen, wie die biologische Zellkultivierung sowie die chemische Analyse und das Screening erfordern die Positionierung und die Handhabung der Tröpfchen in dem Chip. Das Hauptziel dieser Forschungsarbeit war es, einen Mikrofluidik-Chip zu entwerfen, der Tröpfchen auf dem Chip generieren und speichern kann, um weitere Untersuchungen zu ermöglichen und potentielle Applikationen zu erforschen. Zu diesem Zweck wurden mehrere Materialien ausgewählt und untersucht. Letztendlich wurde ein Parylene AF4-beschichteter Polydimethylsiloxan (PDMS)-Chip hergestellt, der diese Anforderungen erfüllt. Die Hauptanwendungen von On-Chip-Speichertröpfchen stehen im direkten Zusammenhang mit der Zellspeicherung und der Zellkultivierung. Diese Anwendungen erfordern einen Mikrochip, der aus einem biokompatiblen Material, wie PDMS oder Parylene hergestellt ist. Um das On-Chip-Speichersystem zu bewerten, wurden Tröpfchen, die biologische Zellen enthielten, erzeugt. Diese verblieben mehr als vier Tage in dem entwickelten Chip. Neben der On-Chip-Speicherung von wässrigen Tröpfchen wurden auch Agarosetröpfchen hergestellt und platziert. Agarose wird häufig als Träger für die Kultivierung menschlicher und tierischer Zellen verwendet. Eine Agaroselösung kann bei geringen Konzentrationen ein stabiles Gel bilden, welches frei von Verunreinigungen ist und nicht an den Zellen haftet. Die Elastizität der Mikroumgebung hat einen signifikanten Einfluss auf das Zellwachstum. Die Agarosetröpfchen ermöglichen die Einkapselung von Zellen, die dann in verschiedenen elastischen Umgebungen kultiviert werden können. In einer durchgeführten Primärstudie wurden Hefezellen in Agarose eingekapselt. Diese Untersuchungen dienten dem Nachweis, dass mechanische Eigenschaften der Umgebung das Zellverhalten beeinflussen können. Um chemische Reaktionen anzuregen und Zellkulturen in Mikrotröpfchen zu realisieren, müssen Mikrotröpfchen aus verschiedenen Flüssigkeitsproben zusammengeführt werden. Die Handhabung der erforderlichen Tröpfchen ist ein weiterer wichtiger Aspekt der tropfenbasierten Mikrofluidik. Es wurde ein Chip entworfen und hergestellt, der Tröpfchen mit frischen Nährstoffen produziert und die gespeicherten Tröpfchen zusammenführt, um deren Zellen mit Nährstoffen zu versorgen. Tröpfchen, die Escherichia coli und Enterococcus faecalis enthielten, wurden mehrere Stunden in dem Chip in AF4-beschichteten PDMS-Kanälen aufbewahrt. Dabei wurde ein bis zu 5 Stunden andauerndes Zellwachstum beobachtet. Da Säugetierzellen jedoch aufgrund des Mangels an Sauerstoff und Kohlendioxid nicht über einen längeren Zeitraum in einem AF4-beschichteten Kanal gelagert werden können, wurde ein Verfahren zur Zufuhr von Sauerstoff zu den in einem Mikrokanal gespeicherten Tröpfchen entwickelt. Nahe den durch fluoriertes Öl getrennten wässrigen Tröpfchen wurden Luftblasen in demselben Mikrofluidikkanal positioniert, um den Sauerstoffgehalt mittels Diffusion anzupassen. Die Überwachung des Sauerstoffgehaltes in den wässrigen Tröpfchen erfolgte mittels des Redoxindikators Methylenblau. Des Weiteren wurden Madin-Darby Canine Kidney (MDCK)-Zellen eingekapselt und in Gegenwart von Luftblasen den Tröpfchen hinzugefügt. In der vorliegenden Forschungsarbeit konnte die Anwendbarkeit von AF4-beschichteten PDMS-Chips für die Speicherung und Kultivierung von Zellen experimentell nachgewiesen werden. Die Herstellung aller Testvorrichtungen erfolgte unter Verwendung schneller und kostengünstiger Methoden.doctoral thesis324 230 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Integration of SiO2 aerogels in microchips and their role as catalyst supports for H₂ combustion devices(2025-10-16); ; ;Barg, SuelenSilica aerogels are porous materials with high specific surface area, open porosity, and low thermal conductivity. These unique properties make them promising candidates for applications such as catalyst supports and thermal insulation. Although silica aerogels have already been incorporated in microsystems; their high shrinkage and fragile behaviour have limited their use to particles, thin films and droplets. This work investigates (I) a process for realising shrinkage-free silica aerogel monoliths inside microfluidic channels and (II) their application as catalytic supports in hydrogen combustion microdevices. The silica aerogels were realised using a sol-gel method with a two-step catalysis. Tetraethyl orthosilicate was used as the silica precursor. To overcome the shrinking and improve the mechanical strength of the aerogels, CO2 supercritical drying and mechanical additives (polyethylene glycol and carbon nanotubes) were applied. Critical process parameters observed were the filling of the microchannels during gelation to avoid shrinkage inside the channel; one week aging time; and twenty exchange cycles during drying to completely remove the ethanol from the pores and avoid pore collapse. The resulting aerogels were successfully integrated in the microchannels without shrinkage. The various compositions of aerogels exhibited high specific surface areas, in a range of 374 to 551 m2/g and mesoporosity. The aerogels were also successfully reinforced by polyethylene glycol and carbon nanotubes (2 to 8 wt.%). The reinforced aerogel monoliths showed an increase of the compressive strength up to three times higher than pure silica aerogels. To explore catalytic applications, the aerogels were functionalized with platinum and ruthenium nanoparticles with concentrations of 2 to 10 wt.%. For this study, a new chip design was used, featuring a polyimide membrane-based open cavity with platinum thermal structures, enabling both the nanoparticle integration and in-situ reaction characterization. Nanoparticles were dispersed in ethanol and infiltrated into the aerogel after drying, ensuring deep penetration and uniform distribution. The catalytic system was characterised using SEM, STEM, EXD, XRD and H2 chemisorption. Additionally, the catalytic combustion was monitored directly in the chip by measuring the resistance change of the thermistor. The final nanoparticle integrated aerogel system could initiate hydrogen combustion in the chip at different loading of Platinum (2 to 10 wt%) and gas composition (0.5 – 2 % vol H2/air). The catalytic reaction also proceeded independently of pre-heating of the system, where a variation of 40oC was measured. Overall, this work establishes a scalable methodology for integrating silica aerogels into microfluidic channels without shrinkage and demonstrates their viability as catalytic supports for platinum nanoparticles in hydrogen combustion devices.doctoral thesis33 59 - Some of the metrics are blocked by yourconsent settings
Item type:Publication, Optofluidic components for biomedical applications(2014-10-07); ; ; In the last years the term Optofluidics has popped up in a large amount of scientific publications. The goal of this thesis is to prove Optofluidics as an applicable, powerful tool for distinct biological and medical applications. In the main part of this work, an optofluidic sensing unit for the determination of liquid concentration is presented. In an experimental evaluation, the sensor was tested with different dissolved molecules including phosphate and lactose. Depending on the analyte, a smallest detectable change in concentration of 10 to 40mmol/L was determined. Besides the sensing device, a new subfield of optofluidics was introduced for the very first time. Thermo-optofluidics deals with the integration of thermal elements in optofluidic systems. Compared to solely solid based realizations more than twice the theoretical switching frequency can be achieved. In conclusion, the applicability of optofluidics for different sensor as well as actuator systems was experimentally proven. All the devices were fabricated applying low-cost, rapid-prototyping fabrication techniques which allow the realization of cost-effective hand-held devices.doctoral thesis284 134
